Show simple item record

Reliability and Validity of the Physical Activity Questionnaire for Pregnant and Lactating Women

dc.contributor.authorวีรชาติ ศรีจันทร์th_TH
dc.contributor.authorWeerachat Srichanen_EN
dc.contributor.authorพัชรี มั่นคงth_TH
dc.contributor.authorPhatchari Mankongen_EN
dc.contributor.authorชาลีลักษม์ ทองประเสริฐth_TH
dc.contributor.authorChaleelak Thongpraserten_EN
dc.contributor.authorทิพวัลย์ พงษ์เจริญth_TH
dc.contributor.authorTippawan Pongcharoenen_EN
dc.contributor.authorอมรพันธ์ อัจจิมาพรth_TH
dc.contributor.authorAmornpan Ajjimapornen_EN
dc.contributor.authorสืบพงษ์ กอวชิรพันธ์th_TH
dc.contributor.authorSueppong Gowachirapanten_EN
dc.date.accessioned2019-03-28T12:39:15Z
dc.date.available2019-03-28T12:39:15Z
dc.date.issued2562-03
dc.identifier.citationวารสารวิจัยระบบสาธารณสุข 13,1 (ม.ค.-มี.ค. 2562) : 90-105th_TH
dc.identifier.issn26729415
dc.identifier.urihttp://hdl.handle.net/11228/5038
dc.description.abstractการศึกษานี้มีวัตถุประสงค์เพื่อพัฒนาและทดสอบความแม่นยำและความเที่ยงตรงของแบบสอบถามกิจกรรมทางกายสำหรับหญิงตั้งครรภ์และหญิงให้นมบุตร (physical activity questionnaire for pregnant and lactating women, PAQ-PL) โดยพัฒนาแบบสอบถามจากแบบประเมินกิจกรรมทางกายสำหรับหญิงตั้งครรภ์ทั้งของไทยและของต่างประเทศ ทดสอบเบื้องต้นโดยการสัมภาษณ์หญิงตั้งครรภ์ หญิงให้นมบุตรและผู้ให้บริการ ทดสอบความแม่นยำ (N=212) โดยให้ทำซ้ำ 2 ครั้ง ห่างกัน 7 วัน และทดสอบความเที่ยงตรงโดยดูความสัมพันธ์กับอุปกรณ์บันทึกการเคลื่อนไหว (accelerometer) (N=86) ในหญิงตั้งครรภ์และหญิงให้นมบุตรที่มารับบริการ ณ โรงพยาบาลส่งเสริมสุขภาพ ศูนย์อนามัยที่ 5 จังหวัดราชบุรี PAQ-PL ที่พัฒนาขึ้นมีรูปแบบเป็นตารางและมีรายการกิจกรรม 21 ข้อ ที่สอดคล้องกับบริบทของหญิงตั้งครรภ์และหญิงให้นมบุตรไทย ความแม่นยำอยู่ในเกณฑ์ดีในการประเมินเวลา (นาที/วัน) ที่ใช้ทำกิจกรรมทางกายโดยรวม กิจกรรมใช้แรงปานกลางถึงหนัก (≥3.0 metabolic equivalents, METs) และกิจกรรมใช้แรงน้อยถึงเบา (<3.0 METs) [intraclass correlation coefficient, ICC = 0.79, 0.84 และ 0.77 ตามลำดับ (p-value <0.05)] ความเที่ยงตรงในการประเมินเวลาที่ใช้ทำกิจกรรมทางกายที่ใช้แรงระดับปานกลางถึงหนักอยู่ในเกณฑ์ที่ยอมรับได้ [Spearman’s correlation, rs = 0.21–0.37 (p-value <0.05)] โดยสรุป PAQ-PL ที่พัฒนาขึ้นมีความแม่นยำปานกลางถึงดีและมีความเที่ยงตรงอยู่ในเกณฑ์ที่ยอมรับได้ โดยเฉพาะการประเมินกิจกรรมทางกายที่ใช้แรงในระดับปานกลางถึงหนัก จึงสามารถนำไปใช้ประเมินกิจกรรมทางกายในหญิงตั้งครรภ์และหญิงให้นมบุตรในระบบบริการสาธารณสุขได้th_TH
dc.description.sponsorshipสถาบันวิจัยระบบสาธารณสุขth_TH
dc.language.isothth_TH
dc.publisherสถาบันวิจัยระบบสาธารณสุขth_TH
dc.rightsสถาบันวิจัยระบบสาธารณสุขth_TH
dc.subjectกิจกรรมทางกายth_TH
dc.subjectphysical activityth_TH
dc.subjectแบบสอบถามth_TH
dc.subjectQuestionnaireth_TH
dc.subjectการสร้างเสริมสุขภาพth_TH
dc.subjectHealth Promotionth_TH
dc.subjectหญิงตั้งครรภ์th_TH
dc.subjectPregnant Womenth_TH
dc.titleความแม่นยำและความเที่ยงตรงของแบบสอบถามกิจกรรมทางกายสำหรับหญิงตั้งครรภ์และหญิงให้นมบุตรth_TH
dc.title.alternativeReliability and Validity of the Physical Activity Questionnaire for Pregnant and Lactating Womenen_EN
dc.typeArticleth_TH
dc.description.abstractalternativeThis study aimed to develop the physical activity questionnaire for pregnant and lactating women (PAQ-PL) and to assess its reliability and validity. The PAQ-PL was developed based on the modification of the previous physical activity questionnaires for pregnant women from Thailand and other countries. The developed PAQ-PL was initially tested to determine the feasibility and acceptability for health care service by interviewing pregnant and lactating women as well as health care service providers. The reliability was assessed by administering the PAQ-PL twice within a 7-day interval (N=212) and the validity was assessed based on the correlation between the PAQ-PL and the accelerometer (N=86) in pregnant and lactating women who visited the Health Promotion Hospital, Health Promotion Center Region 5, Ratchaburi Province. The developed PAQ-PL was in the table format and consisted of 21 items of physical activities (PA) that were appropriate for Thai pregnant and lactating women context. It had good reliability on the time spent (minutes/day) for total PA, moderate-to-vigorous PA (≥3.0 metabolic equivalents, METs), and sedentary- to-light PA (<3.0 METs) [intraclass correlation coefficient, ICC = 0.79, 0.84, and 0.77, respectively (p-value <0.05)]. Its validity was acceptable when used for assessing the time spent on vigorous-to-moderate PA [Spearman’s correlation, rs = 0.21–0.37 (p-value <0.05)]. In summary, the developed PAQ-PL had moderate to good reliability and acceptable validity, especially when considering the assessment of moderate-to-vigorous PA. Hence, it may be feasible to use the PAQ-PL to assess the PA of pregnant and lactating women in the public health service system.en_EN
dc.subject.keywordLactating Womenth_TH
dc.subject.keywordหญิงให้นมบุตรth_TH
.custom.citationวีรชาติ ศรีจันทร์, Weerachat Srichan, พัชรี มั่นคง, Phatchari Mankong, ชาลีลักษม์ ทองประเสริฐ, Chaleelak Thongprasert, ทิพวัลย์ พงษ์เจริญ, Tippawan Pongcharoen, อมรพันธ์ อัจจิมาพร, Amornpan Ajjimaporn, สืบพงษ์ กอวชิรพันธ์ and Sueppong Gowachirapant. "ความแม่นยำและความเที่ยงตรงของแบบสอบถามกิจกรรมทางกายสำหรับหญิงตั้งครรภ์และหญิงให้นมบุตร." 2562. <a href="http://hdl.handle.net/11228/5038">http://hdl.handle.net/11228/5038</a>.
.custom.total_download2900
.custom.downloaded_today0
.custom.downloaded_this_month28
.custom.downloaded_this_year441
.custom.downloaded_fiscal_year64

Fulltext
Icon
Name: hsri-journal-v13n ...